기계설정 번역(한국어 원본) Output group setting |
기계설정 번역(영어 번역본) Output group setting The T50 series is categorized into S (standard) and T (heating/cooling) types, and has both multiple inputs and outputs. The user may select among relay, SSR, or SCR (4~20mA, DC) for output. * In PID control, output interval (Ct) will be 20 seconds if relay-code 3 is selected; when SSR-code 1 is selected, output interval will be automatically set at 2 seconds. You may change this manually. – Setting output amount for the event that input has been cut off If there is a problem with the input sensors or if for any reason the thermometer does not function properly, this safety function shuts off internally controlled output or maintains steady output at a desired level. – Output high/low alarm (OL-H, OL-L) Since the T50 series uses the S-PID algorithm, this function is not necessary in most cases. This function may be used when special circumstances require limiting the output. Using the default value (0~100.0%) is recommended. Input group setting The T50 series supports a wide range of specifications, including 12 types of thermocouples (TC), 2 types of platinum resistance thermometers (RTD), and 3 types of current and voltage inputs. When the input type is changed, all parameters are reverted to their factory default. This means that before using the T50, the input type needs to be set first, after which other parameters can be configured. If the input settings are changed while in use, auto-tuning and other parameters need to be reconfigured. 1) Input type selection This is the first thing that needs to be checked and set before using the T50, as the settings here will cause other parameters to be reset to their typically optimal values for that specific type. Please refer to the “Input type selection codes table” on the next page. 2) Input unit selection (℃ / ℉) This selects the unit of temperature measurement to be displayed when using temperature sensors. The Celsius degree is set as the default, but it may be changed to the Fahrenheit degree. On products sold in Korea, the units are fixed to the Celsius degree in compliance with the regulations. 2) Setting decimal point placement (DP-P), and free scale upper and lower limits (SL-H, SL-L) This applies only when using voltage inputs (DC V, mV) or currents between 4 to 20mA (1~5V). The user may set ranges, units and decimal point placements as desired. This can be used not only for temperatures but also for a number of other measurements, including humidity, pressure, and weight. 1) Digital input filter (FILT) This function is useful when suboptimal environments cause noises or severe fluctuations, enabling a digital software filter. The filter’s sensitivity may be set from off to 1~120 seconds. Please be careful when using this function, as it may affect the control-related algorithms. 2) Input value bias (BIAS) This function allows the input values to be compensated. This function is useful, for example, when sensors cannot be placed at desired locations, or when several different thermometers are used in conjunction. The values may be compensated to extent desired by the user. |
.
이상 기업에서 의뢰한 기계설정 번역(한영번역)의 일부를 살펴 보았습니다.